What Copper-Clad Aluminium Wire Is
Copper-clad aluminium wire is a bimetallic conductor in which an aluminium core is permanently enclosed by a metallurgically bonded copper layer. The composite is produced by cladding and subsequent drawing and annealing, so the two metals are joined atomically along the full length; no adhesive, sleeve or plating is involved. Copper volume fraction is the defining construction parameter, and the standard designations 10A and 15A refer to 10 percent and 15 percent copper by volume.
Electrical Conductivity
The outer copper layer provides a low-resistance current path and a surface that can be soldered and crimped with conventional tooling, while the aluminium core, which is the cheaper metal, carries the bulk of the current. Because aluminium has lower conductivity than copper, the overall conductivity of the composite sits between the two and depends on the copper fraction.
| Conductor | Approximate conductivity, % IACS | Density, g/cm3 | DC resistivity, ohm mm2/m |
|---|---|---|---|
| Copper, annealed | 100 | 8.89 | 0.01724 |
| Copper-clad aluminium 10A | About 65 | 3.32 | 0.0265 |
| Copper-clad aluminium 15A | About 70 | 3.63 | 0.0245 |
| Aluminium, electrical grade | About 61 | 2.70 | 0.02826 |
Values are typical catalogue figures and vary with temper and with the exact cladding ratio, so final conductor sizing should always be based on the supplier datasheet for the specified construction.
Weight and Cost Advantages
Weight reduction is where the material earns most of its place. At a density of about 3.32 g/cm3 for the 10A construction against 8.89 g/cm3 for copper, the composite weighs roughly one third as much as the equivalent solid copper conductor for the same volume, and the aluminium core reduces raw material cost at the same time. Lower mass also means lower transport cost and easier installation where cable trays, connectors and support structures are already at their limit.
Corrosion Behaviour
Copper offers excellent resistance to atmospheric and water corrosion. Aluminium forms a dense, self-renewing oxide film in air that also protects the surface. In the composite, the outer copper layer handles the environment while the aluminium core is protected mechanically by the cladding. The vulnerable points are cut ends and exposed aluminium where moisture and chlorides can reach the core, so terminations should be sealed, and the material is generally not selected for sustained immersion in aggressive chloride service without extra protection.
Mechanical Properties
Annealed copper-clad aluminium wire typically shows tensile strength in the range of 100 to 200 MPa depending on temper and cladding ratio, which is higher than annealed aluminium of the same cross section.
The copper skin carries the outer fibre stress, so bending fatigue performance is better than that of bare aluminium.
Elongation and flex life are adequate for general wiring, but the composite is not a substitute for copper in highly flexed applications such as robotic cable.
Terminations must use connectors rated for copper-clad aluminium; ordinary copper compression lugs may not be listed for the aluminium core.
Applications and Selection Practice
The material is used for coaxial cable conductors, local area network cabling, magnet wire, automotive harnesses and low-frequency power and control cable where weight and cost dominate. Selection should start from the required current carrying capacity and resistance per unit length, then move to the cladding ratio, temper and insulation system. Copper-clad aluminium wire is commonly ordered against ASTM B566, which covers both the 10A and 15A constructions; specifying the standard together with the cladding ratio, diameter and temper removes most sourcing ambiguity.
Design Checks Before Substitution
Replacing solid copper with copper-clad aluminium affects resistance, diameter and termination practice simultaneously. The cross section usually has to increase to match the same voltage drop, and connector selection, soldering or welding methods and the thermal expansion of the joint all need review. Where the application also demands corrosion resistance in a coastal or industrial atmosphere, the sealed termination and the choice of the exposed surface must be confirmed at design stage.
Frequently Asked Questions
Q: Can copper-clad aluminium wire be used to make electrical wires?
Yes, provided the cross section is sized for the slightly higher resistance and terminations are rated for the material; it is widely used in coaxial and network cable.
Q: How much lighter is it than copper?
At about 3.32 g/cm3 for the 10A construction against 8.89 g/cm3 for copper, the composite is roughly one third of the weight for the same volume.
Q: Does the copper layer separate from the aluminium core?
No. The bond is metallurgical and continuous along the full length of the wire, so there is no interface that can open in normal service.
Q: Is it suitable for high-frequency signal cable?
Yes. Skin effect concentrates current in the outer layer at high frequency, so a copper-clad aluminium conductor performs close to solid copper in that regime.
Q: What standard governs the product?
ASTM B566 covers copper-clad aluminium wire and defines the 10A and 15A constructions by copper volume fraction, diameter tolerance and mechanical properties.
Q: Where should it not be used?
Avoid continuous flexing duty, sustained chloride immersion and terminations that are not rated for an aluminium core, unless a suitable protected design is specified.